Kompatibel mit
Thommen Medical® / SPI®
3,5 mm
TITANIUM BASE
incl. screw
THO 80350000
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D3.500
nt-Mill Lab Analog
THO 5.La3.500
Implant Pick-Up
for open-tray with integrated screw
THO TR-00013.5
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 603500
DIM Analog®
THO 5.DIM.350
Sleeve (belongs to DIM ANALOG)
plaster model
DIM 5.XSL.A10
nt-Preform®
incl. coloured milling screw
Recommended screwdriver W 11.THO.MIL 4-socket
THO 10.Mi3.500.05
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D3.500
nt-Mill Lab Analog
for NT-Preform®
THO 5.La3.500
Coloured Milling Screw
for NT-Preform®
Recommended screwdriver W 11.THO.MIL 4-socket
THO 6.Sc3.500
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 603500
DIM Analog®
THO 5.DIM.350
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A10
Abutment Grip
for NT-Holder fixture
W 12.100.000
Customized Abutment
individual milled by NT-iDent
TZ15.TiO.Si1
2-CONnect®-Abutment Set (STRAIGHT)
incl. 2-CONnect®-Coping and Coping-screw
GH 0,5 mm
THO-2CON 8035001S
GH 2,5 mm
THO-2CON 8035002S
2-CONnect®-Abutment
Male Part
GH 0,5 mm
THO-2CON 8035001M
GH 2,5 mm
THO-2CON 8035002M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanning\r\nKS 60 = 1,4 mm
2CON 9.S3D1.400
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 60
2-CONnect®-DIM Analog®
KS 60 = 1,4 mm
2CON 5.DIM.140
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw
KS 60 = 1,4 mm
2CON 9.S3D1.400
2-CONnect®-Lab Analog
KS 60 = 1,4 mm
2CON 5.La1.400
2-CONnect®-Abutment Set (ANGLED)
incl. 2-CONnect®-Coping, mounting aid,
Coping-screw and Male Part Screw, angled 20°,
Gingiva Height 2,5 mm
THO-2CON 80350A3S
2-CONnect®-Abutment
angled 20°, Gingiva Height 2,5 mm
Male Part inclusive Screw
mounting aid
THO-2CON 80350A3M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanning\r\nKS 62 = 1,6 mm
2CON 9.S3D1.600
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 62
Male Part Screw
for angled 20° 2-CONnect® Abutment
Recommended tightening torques: 20 Ncm
THO 6.Ms3.500
2-CONnect®-DIM Analog®
KS 62 = 1,6 mm
2CON 5.DIM.160
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw,
KS 62 = 1,6 mm
2CON TR-00031.6
2-CONnect®-Lab Analog
KS 62 = 1,6 mm
2CON 5.La1.600
4,0 mm
TITANIUM BASE
incl. screw
THO 80400000
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D4.000
nt-Mill Lab Analog
THO 5.La4.000
Implant Pick-Up
for open-tray with integrated screw
THO TR-00024.0
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.400
Sleeve (belongs to DIM ANALOG)
plaster model
DIM 5.XSL.A20
nt-Preform®
incl. coloured milling screw
Recommended screwdriver W 11.THO.MIL 4-socket
THO 10.Mi4.000.05
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D4.000
nt-Mill Lab Analog
for NT-Preform®
THO 5.La4.000
Coloured Milling Screw
for NT-Preform®
Recommended screwdriver W 11.THO.MIL 4-socket
THO 6.Sc4.060
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.400
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A20
Abutment Grip
for NT-Holder fixture
W 12.200.000
Customized Abutment
individual milled by NT-iDent
TZ15.TiO.Si1
2-CONnect®-Abutment Set (STRAIGHT)
incl. 2-CONnect®-Coping and Coping-screw
GH 0,5 mm
THO-2CON 8040001S
GH 2,5 mm
THO-2CON 8040002S
2-CONnect®-Abutment
Male Part
GH 0,5 mm
THO-2CON 8040001M
GH 2,5 mm
THO-2CON 8040002M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanning\r\nKS 60 = 1,4 mm
2CON 9.S3D1.400
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 60
2-CONnect®-DIM Analog®
KS 60 = 1,4 mm
2CON 5.DIM.140
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw
KS 60 = 1,4 mm
2CON 9.S3D1.400
2-CONnect®-Lab Analog
KS 60 = 1,4 mm
2CON 5.La1.400
2-CONnect®-Abutment Set (ANGLED)
incl. 2-CONnect®-Coping, mounting aid,
Coping-screw and Male Part Screw, angled 20°,
Gingiva Height 2,5 mm
THO-2CON 80400A3S
2-CONnect®-Abutment
angled 20°, Gingiva Height 2,5 mm
Male Part inclusive Screw,
mounting aid
THO-2CON 80400A3M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanning\r\nKS 62 = 1,6 mm
2CON 9.S3D1.600
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 62
Male Part Screw
for angled 20° 2-CONnect® Abutment
Recommended tightening torques: 20 Ncm
THO 6.Ms4.060
2-CONnect®-DIM Analog®
KS 62 = 1,6 mm
2CON 5.DIM.160
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw,
KS 62 = 1,6 mm
2CON TR-00031.6
2-CONnect®-Lab Analog
KS 62 = 1,6 mm
2CON 5.La1.600
4,5 mm
TITANIUM BASE
incl. screw
THO 80450000
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D4.500
nt-Mill Lab Analog
THO 5.La4.500
Implant Pick-Up
for open-tray with integrated screw
THO TR-00034.5
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.450
Sleeve (belongs to DIM ANALOG)
plaster model
DIM 5.XSL.A20
nt-Preform®
incl. coloured milling screw
Recommended screwdriver W 11.THO.MIL 4-socket
THO 10.Mi4.500.05
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D4.500
nt-Mill Lab Analog
for NT-Preform®
THO 5.La4.500
Coloured Milling Screw
for NT-Preform®
Recommended screwdriver W 11.THO.MIL 4-socket
THO 6.Sc4.060
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.450
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A20
Abutment Grip
for NT-Holder fixture
W 12.200.000
Customized Abutment
individual milled by NT-iDent
TZ15.TiO.Si1
2-CONnect®-Abutment Set (STRAIGHT)
incl. 2-CONnect®-Coping and Coping-screw
GH 0,5 mm
THO-2CON 8045001S
GH 2,5 mm
THO-2CON 8045002S
2-CONnect®-Abutment
Male Part
GH 0,5 mm
THO-2CON 8045001M
GH 2,5 mm
THO-2CON 8045002M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanningKS 61 = 1,8 mm
2CON 9.S3D1.800
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 20 Ncm
KS 61
2-CONnect®-DIM Analog®
KS 61 = 1,8 mm
2CON 5.DIM.180
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw
KS 61 = 1,8 mm
2CON TR-00021.8
2-CONnect®-Lab Analog
KS 61 = 1,8 mm
2CON 5.La1.800
2-CONnect®-Abutment Set (ANGLED)
incl. 2-CONnect®-Coping, mounting aid,
Coping-screw and Male Part Screw, angled 20°,
Gingiva Height 2,5 mm
THO-2CON 80450A3S
2-CONnect®-Abutment
angled 20°, Gingiva Height 2,5 mm
Male Part inclusive Screw,
mounting aid
THO-2CON 80450A3M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanningKS 62 = 1,6 mm
2CON 9.S3D1.600
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 62
Male Part Screw
for angled 20° 2-CONnect® Abutment
Recommended tightening torques: 20 Ncm
THO 6.Ms4.060
2-CONnect®-DIM Analog®
KS 62 = 1,6 mm
2CON 5.DIM.160
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw,
KS 62 = 1,6 mm
2CON TR-00031.6
2-CONnect®-Lab Analog
KS 62 = 1,6 mm
2CON 5.La1.600
5,0 mm
TITANIUM BASE
incl. screw
THO 80500000
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D5.000
nt-Mill Lab Analog
THO 5.La5.000
Implant Pick-Up
for open-tray with integrated screw
THO TR-00045.0
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.500
Sleeve (belongs to DIM ANALOG)
plaster model
DIM 5.XSL.A30
nt-Preform®
incl. coloured milling screw
Recommended screwdriver W 11.THO.MIL 4-socket
THO 10.Mi5.000.05
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D5.000
nt-Mill Lab Analog
for NT-Preform®
THO 5.La5.000
Coloured Milling Screw
for NT-Preform®
Recommended screwdriver W 11.THO.MIL 4-socket
THO 6.Sc4.060
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.500
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
Abutment Grip
for NT-Holder fixture
W 12.300.000
Customized Abutment
individual milled by NT-iDent
TZ15.TiO.Si1
2-CONnect®-Abutment Set (STRAIGHT)
incl. 2-CONnect®-Coping and Coping-screw
GH 0,5 mm
THO-2CON 8050001S
GH 2,5 mm
THO-2CON 8050002S
2-CONnect®-Abutment
Male Part
GH 0,5 mm
THO-2CON 8050001M
GH 2,5 mm
THO-2CON 8050002M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanningKS 61 = 1,8 mm
2CON 9.S3D1.800
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 20 Ncm
KS 61
2-CONnect®-DIM Analog®
KS 61 = 1,8 mm
2CON 5.DIM.180
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw
KS 61 = 1,8 mm
2CON TR-00021.8
2-CONnect®-Lab Analog
KS 61 = 1,8 mm
2CON 5.La1.800
2-CONnect®-Abutment Set (ANGLED)
incl. 2-CONnect®-Coping, mounting aid,
Coping-screw and Male Part Screw, angled 20°,
Gingiva Height 2,5 mm
THO-2CON 80500A3S
2-CONnect®-Abutment
angled 20°, Gingiva Height 2,5 mm
Male Part inclusive Screw,
mounting aid
THO-2CON 80500A3M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanningKS 62 = 1,6 mm
2CON 9.S3D1.600
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 62
Male Part Screw
for angled 20° 2-CONnect® Abutment
Recommended tightening torques: 20 Ncm
THO 6.Ms4.060
2-CONnect®-DIM Analog®
KS 62 = 1,6 mm
2CON 5.DIM.160
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw,
KS 62 = 1,6 mm
2CON TR-00031.6
2-CONnect®-Lab Analog
KS 62 = 1,6 mm
2CON 5.La1.600
6,0 mm
TITANIUM BASE
incl. screw
THO 80600000
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D6.000
nt-Mill Lab Analog
THO 5.La6.000
Implant Pick-Up
for open-tray with integrated screw
THO TR-00056.0
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.600
Sleeve (belongs to DIM ANALOG)
plaster model
DIM 5.XSL.A30
nt-Preform®
incl. coloured milling screw
Recommended screwdriver W 11.THO.MIL 4-socket
THO 10.Mi6.000.05
Scan Body 3D-Guide®
for intra + extra oral scanning
THO 9.S3D6.000
nt-Mill Lab Analog
for NT-Preform®
THO 5.La6.000
Coloured Milling Screw
for NT-Preform®
Recommended screwdriver W 11.THO.MIL 4-socket
THO 6.Sc4.060
Abutment Screw
Overview of all screwdrivers on pages 344 and 345
THO 604060
DIM Analog®
THO 5.DIM.600
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
Abutment Grip
for NT-Holder fixture
W 12.300.000
Customized Abutment
individual milled by NT-iDent
TZ15.TiO.Si1
2-CONnect®-Abutment Set (STRAIGHT)
incl. 2-CONnect®-Coping and Coping-screw
GH 0,5 mm
THO-2CON 8060001S
GH 2,5 mm
THO-2CON 8060002S
2-CONnect®-Abutment
Male Part
GH 0,5 mm
THO-2CON 8060001M
GH 2,5 mm
THO-2CON 8060002M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanningKS 61 = 1,8 mm
2CON 9.S3D1.800
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 20 Ncm
KS 61
2-CONnect®-DIM Analog®
KS 61 = 1,8 mm
2CON 5.DIM.180
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw
KS 61 = 1,8 mm
2CON TR-00021.8
2-CONnect®-Lab Analog
KS 61 = 1,8 mm
2CON 5.La1.800
2-CONnect®-Abutment Set (ANGLED)
incl. 2-CONnect®-Coping, mounting aid,
Coping-screw and Male Part Screw, angled 20°,
Gingiva Height 2,5 mm
THO-2CON 80600A3S
2-CONnect®-Abutment
angled 20°, Gingiva Height 2,5 mm
Male Part inclusive Screw,
mounting aid
THO-2CON 80600A3M
2-CONnect®-Scan Body 3D-Guide®
for intra + extra oral scanningKS 62 = 1,6 mm
2CON 9.S3D1.600
2-CONnect®-Coping
Female Part
2CON F-U
Coping-Screw
Recommended tightening torques: 15 Ncm
KS 62
Male Part Screw
for angled 20° 2-CONnect® Abutment
Recommended tightening torques: 20 Ncm
THO 6.Ms4.060
2-CONnect®-DIM Analog®
KS 62 = 1,6 mm
2CON 5.DIM.160
Sleeve (belongs to DIM ANALOG®)
plaster model
DIM 5.XSL.A30
2-CONnect®-Implant Pick-Up
integrated screw,
KS 62 = 1,6 mm
2CON TR-00031.6
2-CONnect®-Lab Analog
KS 62 = 1,6 mm
2CON 5.La1.600